MICRO MÉCANIQUE offers a comprehensive range of microscopy solutions, cameras, lenses, lighting, motorised stages, incubation chambers and accessories. We support you from selection to installation, including training and maintenance, to optimise your observations and protocols, from teaching laboratories to advanced research.

Electrophysiology & Neuroscience

For over 35 years, MICRO MÉCANIQUE SAS has been supporting researchers and laboratories in neuroscience, electrophysiology and optogenetics. We offer a comprehensive range of equipment (amplifiers, micromanipulators, microinjection systems, etc.) and comprehensive support: advice, installation, training and maintenance throughout France.

Model 1800 amplifier – A-M Systems

The A-M Systems Model 1800 amplifier is a 2-channel AC differential amplifier with preamplifier (headstage), designed for extracellular recording and stimulation applications with high-impedance microelectrodes.

Description of the A-M Systems Model 1800 amplifier

Ideal for recording single-cell action potentials (spikes), EEG, EMG, EKG, ERG and evoked potentials in research and teaching laboratories.

Features of the A-M Systems Model 1800 amplifier

  • 2 independent channels, including headstages
  • Fixed gain ×100, ×1,000, ×10,000
  • Low noise: ~1.0 µV peak-to-peak (10 Hz-10 kHz)
  • Common mode rejection > 80 dB (up to 110 dB depending on source)
  • Effective notch filter (> 25 dB at 50 Hz / > 30 dB at 60 Hz)
  • High input impedance > 100,000 MΩ
  • Low bias current ± 3 pA typical, max ± 20 pA
  • High-pass filters: 0.1, 1, 10, 100, 300 Hz
  • Low-pass filters: 500, 1 k, 5 k, 10 k, 20 k Hz
  • Modes: Record, Stimulate, Impedance check (in situ)
  • Current measurement during stimulation via internal 1 kΩ resistor
  • Sampling heads included with 1.5 m rigid cables
  • Power supply: 110 V/60 Hz or 220 V/50 Hz
  • Standard 3-year warranty

Technical characteristics of the A-M Systems Model 1800 amplifier

Caractéristique Valeur
Channels 2 differential amplifiers with headstages
Gain ×100, ×1 000, ×10 000
Noise 1.0 µV p-p typical (10 Hz-10 kHz)
Common mode rejection > 80 dB (up to 110 dB at 60 Hz)
Notch filter > 25 dB at 50 Hz, > 30 dB at 60 Hz
Input impedance > 100,000 MΩ
Polarisation current ± 3 pA typical, ± 20 pA max
High-pass filters 0.1 / 1 / 10 / 100 / 300 Hz
Low-pass filters 500 Hz / 1 k / 5 k / 10 k / 20 k Hz
Mode selection Record / Stimulate / Impedance Check
Internal resistance (Stim/Impede.) 1 kΩ (current/stimulation)
Headstage 0.535″ Ø × 4″, rod 4.7 mm, cable 1.5 m
Power supply 110 V / 60 Hz or 220 V / 50 Hz
Dimensions (W×H×D) 43.2 × 12.1 × 28.6 cm
Consumption < 5 W
Accessories included 2 headstages, cables, rack mount, manual
Guarantee 3 years

Applications

  • Extracellular recordings of cellular spikes, multi-units
  • EEG, EMG, EKG, ERG and evoked potentials
  • Verification of electrode impedance in situ