MICRO MÉCANIQUE offers a comprehensive range of microscopy solutions, cameras, lenses, lighting, motorised stages, incubation chambers and accessories. We support you from selection to installation, including training and maintenance, to optimise your observations and protocols, from teaching laboratories to advanced research.

Electrophysiology & Neuroscience

For over 35 years, MICRO MÉCANIQUE SAS has been supporting researchers and laboratories in neuroscience, electrophysiology and optogenetics. We offer a comprehensive range of equipment (amplifiers, micromanipulators, microinjection systems, etc.) and comprehensive support: advice, installation, training and maintenance throughout France.

Z-Stage Piezo Z-axis motorisation

The Märzhäuser Piezo Z-Stage enables fast, precise and stable positioning of the sample on the Z axis. Designed for easy integration into inverted or upright microscopes, it offers displacements in the nanometre range in just a few milliseconds. Two versions are available with travels of 300 µm or 500 µm, compatible with Märzhäuser controllers.

Features of the Z-Stage Piezo Z-Axis Motorisation System

  • Available strokes: 300 µm (USB/analogue) or 500 µm (EBD/WSB controller)
  • High-resolution Z positioning (down to 1 nm)
  • Fast stabilisation: 10 to 25 ms depending on model
  • Load capacity up to 1.5 kg (500 µm model)
  • Capacitive or integrated position sensor, depending on version
  • Multiple interfaces: USB, RS-232, CAN, Ethernet, analogue inputs/outputs and triggers
  • Direct compatibility with TANGO systems and standard inserts (blades, wells, boxes)

Technical specifications of the Z-Stage Piezo Z-Axis Motorization

Caractéristique Valeur
Race 300 µm (USB/analogue) or 500 µm (EBD/WSB)
Resolution 1 nm (500 µm), 4-31 nm (300 µm depending on interface)
Repeatability ±5 nm (500 µm), 4 nm unidirectional (300 µm)
Linearity < 0.05% (500 µm), 2% (300 µm)
Stabilisation time 10 ms (500 µm), 25 ms (300 µm)
Max. supported load 0.3-1.5 kg depending on version
Interface USB, Ethernet, RS-232, CAN, analogue, triggers
Operating temperature -20 to +80 °C (300 µm), +10 to +40 °C (500 µm)
Weight ~1 kg with cable (2 m)
Material Anodised aluminium

Applications

  • Fine focus adjustment in inverted microscopy
  • Confocal or fluorescence imaging requiring rapid focusing
  • Automated 3D volume scanning
  • Integration into screening systems or analysis robots

Documentation

Brochure

PDF file780.8 ko

Brochure part 2

PDF file761.8 ko